PVC-M Pipe for Water Supply
PVC-M pipe for water supply, while maintaining the advantages of PVC-U pipe, improves the pipe’s ability to resist water hammer and point load, with better toughness and higher strength.
1.Raw material:(1)Unplasticized polyvinyl chloride with toughener;
2.Diameter Range: (2) From 63mm-800mm;
3.Pressure Rating: PN8- PN25;
4.Standard: ISO,DIS 16422, GB/T 32018, etc;
5.Application:Water supply pipeline, mining water supply pipeline, trenchless pipeline, etc;
6.Delivery:(6)10-30 days depending on the total quantity;
7.CO(Certificate of Origin): China, CO could be provided by free;
8.MOQ: Retail or Bulk orders acceptable;
9.Production Inspection:QA system, Raw Material Test Report, Third-Party Inspection.
✉ E-mail: [email protected] ☎ Mobile: +8615515596408(WhatsApp/Wechat)
EXTRA VALUABLE SERVICE
✧High Quality: ISO certificated ✧Global Transportation Service
✧Free samples& Free Design ✧Full Satisfaction Guaranteed: 5 Years
Description
Description of PVC-M Pipe for Water Supply
PVC-M water supply pipe, impact-resistant modified polyvinyl chloride PVC-M pipe for water supply, is based on the production formula of PVC-U pipe, adding toughener, controlling equipment process, so as to obtain PVC-M pipe with better toughness and higher strength.
The toughening modification methods are divided into chemical toughening and physical toughening. While maintaining the elastic modulus of PVC-U pipe, PVC-M pipe improves the flexibility of the pipe. Its toughness is between PVC-U and PE. Good flexibility improves the ability of the pipe to resist water hammer and point load, and improves the safety of pipeline operation. PVC-M pipe for water supply has the advantages of PVC-U, and its impact resistance and flexibility are significantly improved. It has been widely used in water supply pipeline, as well as mine water supply, trenchless laying pipeline and other harsh environments, with excellent performance. Different countries use different names for PVC M pipes. The United States and Australia call it PVC-M, Japan and the Netherlands call it PVC-HI, and the United Kingdom calls it PVC-A.
Advantages of PVC-M Pipe for Water Supply
1、Better toughness than PVC-U, strong impact and explosion resistance
2、Resistance to water hammer and point impact, limited reduction of damage during operation
3、Corrosion and chemical resistance
4、Stronger water delivery capacity
5、Lightweight, easy to transport and install
6、Smaller pipe wall thickness, reduced raw material consumption, more economical
Please Contact us to Get More Details, Send Email: [email protected]. or Mobile:(WhatsApp): +86 155 15596408.
Specification
Specification of PVC-M Pipe for Water Supply
Nominal Outside Diameter dn(mm) |
Pipe Series S and Nominal Pressure PN | Rubber Ring Joints Minimum Socket Depth mmin |
Solvent Cement Joints Minimum Socket Depth mmin |
||||
S20 | S16 | S12.5 | S10 | S8 | |||
SDR41 | SDR33 | SDR26 | SDR21 | SDR17 | |||
PN8 | PN10 | PN12.5 | PN16 | PN20 | |||
Nominal Wall Thickness en | |||||||
63 | 2.0 | 2.0 | 2.5 | 3.0 | 3.8 | 64.0 | 37.5 |
75 | 2.0 | 2.3 | 2.9 | 3.6 | 4.5 | 67.0 | 43.5 |
90 | 2.2 | 2.8 | 3.5 | 4.3 | 5.4 | 70.0 | 51.0 |
110 | 2.7 | 3.4 | 4.2 | 5.3 | 6.6 | 75.0 | 61.0 |
125 | 3.1 | 3.9 | 4.8 | 6.0 | 7.4 | 78.0 | 68.5 |
140 | 3.5 | 4.3 | 5.4 | 6.7 | 8.3 | 81.0 | 76.0 |
160 | 4.0 | 4.9 | 6.2 | 7.7 | 9.5 | 86.0 | 86.0 |
180 | 4.4 | 5.5 | 6.9 | 8.6 | 10.7 | 90.0 | 96.0 |
200 | 4.9 | 6.2 | 7.7 | 9.6 | 11.9 | 94.0 | 106.0 |
225 | 5.5 | 6.9 | 8.6 | 10.8 | 13.4 | 100.0 | 118.5 |
250 | 6.2 | 7.7 | 9.6 | 11.9 | 14.8 | 105.0 | – |
280 | 6.9 | 8.6 | 10.7 | 13.4 | 16.6 | 112.0 | – |
315 | 7.7 | 9.7 | 12.1 | 15.0 | 18.7 | 118.0 | – |
355 | 8.7 | 10.9 | 13.6 | 16.9 | 21.1 | 124.0 | – |
400 | 9.8 | 12.3 | 15.3 | 19.1 | 23.7 | 130.0 | – |
450 | 11.0 | 13.8 | 17.2 | 21.5 | 26.7 | 138.0 | – |
500 | 12.3 | 15.3 | 19.1 | 23.9 | 29.7 | 145.0 | – |
560 | 13.7 | 17.2 | 21.4 | 26.7 | – | 154.0 | – |
630 | 15.4 | 19.3 | 24.1 | 30.0 | – | 165.0 | – |
710 | 17.4 | 21.8 | 27.2 | – | – | 177.0 | – |
800 | 19.6 | 24.5 | 30.6 | – | – | 190.0 | – |
1: The minimum required strength of the pipe is not less than 24.5MPa, the nominal wall thickness (en) is determined according to the design stress (as) 16MPa, and the minimum wall thickness of the pipe is 2.0mm. 2:“-” Indicates not recommended. 3:When the length of the pipe is longer than 12 m, the rubber ring joints socket depth mmin needs to be designed separately. |
Other specifications have not been shown on our dimension chart, please CONTACT US for more information.
Please Send Email: [email protected] or Mobile:(WhatsApp): +86 155 15596408.
Application
Application of PVC-M Pipe for Water Supply
1.Municipal water supply
2.Mine pipeline
3.Trenchless pipeline
4.Transportation for corrosive medium
5.Garden irrigation
6.Sewage treatment plant
PVC-M Pipe for Water Supply | PVC-M Pipe for Mine Pipeline |
PVC-M Pipe for Trenchless pipeline | PVC-M Pipe for Trenchless pipeline |
For more details, please CONTACT US soon.
Please Send Email: [email protected] or Mobile:(WhatsApp): +86 155 15596408.
Enquiry
Get the PVC-M Pipe for Water Supply Price Now!
Please CONTACT US for more information and Quotation Now!
Please Send Email: [email protected] or Mobile:(WhatsApp): +86 155 15596408.